<?xml version="1.0" encoding="UTF-8"?>
<?xml-model href="https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1D00.sch" schematypens="http://purl.oclc.org/dsdl/schematron"?>
<Product_Observational xmlns="http://pds.nasa.gov/pds4/pds/v1"
    xmlns:pds="http://pds.nasa.gov/pds4/pds/v1"
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://pds.nasa.gov/pds4/pds/v1  https://pds.nasa.gov/pds4/pds/v1/PDS4_PDS_1D00.xsd">
    <Identification_Area>
        <logical_identifier>urn:nasa:pds:jno.rss.raw.jugr:data.tnf:grv_jugr_2025323_0000x63mc001v01</logical_identifier>
        <version_id>1.0</version_id>
        <title>Juno TRK234 Labels</title>
        <information_model_version>1.13.0.0</information_model_version>
        <product_class>Product_Observational</product_class>
        <Modification_History>
            <Modification_Detail>
                <modification_date>2025-11-19</modification_date>
                <version_id>1.0</version_id>
                <description>
                    Label for TRK234 Data products
                </description>
            </Modification_Detail>
        </Modification_History>
    </Identification_Area>
    <Observation_Area>
        <comment>
         Report for File: GRV_JUGR_2025323_0000X63MC001V01.TNF
         Generation Date: 2025-323T20:50:05
              Start Time: 2025-323T00:00:15
                End Time: 2025-323T10:35:24
           Spacecraft ID: 61
         Downlink DSS ID: 63
          Downlink Bands: X
      Doppler Count Time: 1.0
           Uplink DSS ID: 63
            Uplink Bands: X
           Tracking Mode: 3W/55, 1W, 3W/25
       Number of Records: 130190
    Data Description IDs: C125, C123, C124
    Available Data Types: 0, 1, 9, 16, 17
                      00: Uplink Carrier Phase - 38110
                      01: Downlink Carrier Phase - 30692
                      09: Ramps - 10
                      16: Carrier Observable - 30689
                      17: Total Phase Observable - 30689
        </comment>
        <Time_Coordinates>
            <start_date_time>2025-11-19T00:00:15Z</start_date_time>
            <stop_date_time>2025-11-19T10:35:24Z</stop_date_time>
        </Time_Coordinates>
        <Primary_Result_Summary>
            <purpose>Science</purpose>
            <processing_level>Raw</processing_level>
            <description>
    The TNF data type captures radiometric tracking data for delivery
    to navigation and radio science users from the Telecommunications
    Services at JPL.  The product replaces data types formerly known
    as Orbit Data Files, Archival Tracking Data Files, and others.
    Format and content of the TNF data product is documented in:

                              820-013
                   Deep Space Mission System (DSMS)
                   External Interface Specification
                            JPL D-16765
                             TRK-2-34
               DSMS Tracking System Data Archival Format
                      Jet Propulsion Laboratory
                        4800 Oak Grove Drive
                      Pasadena, CA  91109-8099

    Background information on the radiometric system may be found in:

             Formulation for Observed and Computed Values
           of Deep Space Network Data Types  for Navigation
                         by Theodore D. Moyer
                  JPL Publication 00-7, October 2000
     Monograph 2, Deep Space Communications and Navigation Series
                      Jet Propulsion Laboratory
                        4800 Oak Grove Drive
                      Pasadena, CA  91109-8099
            </description>
        </Primary_Result_Summary>

        <Investigation_Area>
            <name>JUNO</name>
            <type>Mission</type>
            <Internal_Reference>
                <lid_reference>urn:nasa:pds:context:investigation:mission.juno</lid_reference>
                <reference_type>data_to_investigation</reference_type>
            </Internal_Reference>
        </Investigation_Area>
        <Observing_System>
            <name>Juno Gravity Science</name>
            <Observing_System_Component>
                <name>JUNO</name>
                <type>Spacecraft</type>
                <Internal_Reference>
                    <lid_reference>urn:nasa:pds:context:instrument_host:spacecraft.jno</lid_reference>
                    <reference_type>is_instrument_host</reference_type>
                </Internal_Reference>
            </Observing_System_Component>
            <Observing_System_Component>
                <name>GRAV</name>
                <type>Instrument</type>
                <description>Gravity Science Investigation</description>
                <Internal_Reference>
                    <lid_reference>urn:nasa:pds:context:instrument:juno.rss</lid_reference>
                    <reference_type>is_instrument</reference_type>
                </Internal_Reference>
            </Observing_System_Component>
        </Observing_System>
        <Target_Identification>
            <name>Earth</name>
            <type>Planet</type>
            <Internal_Reference>
                <lid_reference>urn:nasa:pds:context:target:planet.earth</lid_reference>
                <reference_type>data_to_target</reference_type>
            </Internal_Reference>
        </Target_Identification>
        <Target_Identification>
            <name>Jupiter</name>
            <type>Planet</type>
            <Internal_Reference>
                <lid_reference>urn:nasa:pds:context:target:planet.jupiter</lid_reference>
                <reference_type>data_to_target</reference_type>
            </Internal_Reference>
        </Target_Identification>
    </Observation_Area>

    <Reference_List>
        <Internal_Reference>
            <lid_reference>urn:nasa:pds:juno.rss.raw.jugr:document:juno_grav_sis</lid_reference>
            <reference_type>data_to_document</reference_type>
        </Internal_Reference>
    </Reference_List>    

    <File_Area_Observational>
        <File>
            <file_name>GRV_JUGR_2025323_0000X63MC001V01.TNF</file_name>
            <local_identifier>trk_TableBinary</local_identifier>
            <creation_date_time>2025-11-19T10:35:24Z</creation_date_time>
            <file_size unit="byte">32533220</file_size>
            <records>130190</records>
            <md5_checksum>8dfc05fb21363faacf1a45f3b2e34cca</md5_checksum>
        </File>

        <Table_Binary>
            <local_identifier>trk_TableBinary_SFDU_00</local_identifier>
            <offset unit="byte">0</offset>
            <records>38110</records>
            <Record_Binary>
                <fields>65</fields>
                <groups>0</groups>
                <record_length unit="byte">182</record_length>
                <Field_Binary>
                    <name>control_auth_id</name>
                    <field_number>1</field_number>
                    <field_location unit="byte">1</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Control authority identifier. ;  NJPL  indicates that the data description information for this SFDU is maintained and disseminated by NASA/JPL.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_version_id</name>
                    <field_number>2</field_number>
                    <field_location unit="byte">5</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU label version ID.;  2  indicates that the length attribute field in bytes 12 to 19 is formatted as a binary unsigned integer.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_class_id</name>
                    <field_number>3</field_number>
                    <field_location unit="byte">6</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU class ID.;  I  indicates that this SFDU contains data to be used by an application process.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>4</field_number>
                    <field_location unit="byte">7</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>data_description_id</name>
                    <field_number>5</field_number>
                    <field_location unit="byte">9</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Data description identifier.; Uniquely identifies the data description information held by the control authority identified in the  Control authority identifier  item for this type of SFDU.; C123 => Uplink types; C124 => Downlink types; C125 => Derived types; C126 => Interferometric types; C127 => Filtered types</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_length</name>
                    <field_number>6</field_number>
                    <field_location unit="byte">13</field_location>
                    <data_type>UnsignedMSB8</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the tracking data SFDU.; Indicates the length of the data following this element.; DT0 => 162; DT1 => 358 ; DT2 => 194 ; DT3 => 304 ; DT4 => 276 ; DT5 => 388 ; DT6 => 200; DT7 => 330; DT8 => 178 ; DT9 => 124; DT10 => 204 ; DT11 => 182; DT12 => 164 ; DT13 => 160; DT14 => 348; DT15 => 194; DT16 => 182 + 18 * num_obs; DT17 => 194 + 22 * num_obs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>7</field_number>
                    <field_location unit="byte">21</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the aggregation CHDO.; A value of 1 indicates that this CHDO is an aggregation of CHDOs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>8</field_number>
                    <field_location unit="byte">23</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the aggregation CHDO.; Indicates the length of the sum of the primary and secondary CHDOs.; CHDO 132 => 78; CHDO 133 => 122; CHDO 134 => 136; CHDO 135 => 100; CHDO 136 => 110</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>9</field_number>
                    <field_location unit="byte">25</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the primary CHDO.; A value of 2 indicates that this CHDO is a primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>10</field_number>
                    <field_location unit="byte">27</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the primary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mjr_data_class</name>
                    <field_number>11</field_number>
                    <field_location unit="byte">29</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Major data class.; A value of 6 indicates that the data in this SFDU is ground station monitor data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mnr_data_class</name>
                    <field_number>12</field_number>
                    <field_location unit="byte">30</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Minor data class.; Indicates data is processed tracking data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mission_id</name>
                    <field_number>13</field_number>
                    <field_location unit="byte">31</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Mission ID.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>format_code</name>
                    <field_number>14</field_number>
                    <field_location unit="byte">32</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Format code.; Also referred to as the data type.;   0  =>  Uplink Carrier Phase;   1  =>  Downlink Carrier Phase;   2  =>  Uplink Sequential Ranging Phase;   3  =>  Downlink Sequential Ranging Phase;   4  =>  Uplink PN Ranging Phase;   5  =>  Downlink PN Ranging Phase;   6  =>  Doppler;   7  =>  Sequential Ranging;   8  =>  Angles;   9  =>  Ramps ; 10  =>  VLBI; 11  =>  DRVID ; 12  =>  Smoothed Noise; 13  =>  Allan Deviation; 14  =>  PN Ranging; 15  =>  Tone Ranging; 16  =>  Carrier Observable; 17  =>  Total Phase Observable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>15</field_number>
                    <field_location unit="byte">33</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the secondary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>16</field_number>
                    <field_location unit="byte">35</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the secondary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the secondary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>orig_id</name>
                    <field_number>17</field_number>
                    <field_location unit="byte">37</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Originator ID.; Indicates where this SFDU was originated. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>last_modifier_id</name>
                    <field_number>18</field_number>
                    <field_location unit="byte">38</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Last modifier ID.; Indicates where the contents of this SFDU were last modified. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1</name>
                    <field_number>19</field_number>
                    <field_location unit="byte">39</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.  ; For future expansion of scft_id.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_id</name>
                    <field_number>20</field_number>
                    <field_location unit="byte">40</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft number.;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>upl_rec_seq_num</name>
                    <field_number>21</field_number>
                    <field_location unit="byte">41</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Uplink record sequence number (UPL RSN).; This is the record sequence number reported by the uplink subsystem (UPL) equipment.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rec_seq_num</name>
                    <field_number>22</field_number>
                    <field_location unit="byte">45</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Record sequence number (RSN).; Begins with zero; increments by one for each successive uplink tracking SFDU of the same data type; wraps around from 232-1 to zero. Value is reset to zero when the data processing system software is restarted.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>year</name>
                    <field_number>23</field_number>
                    <field_location unit="byte">49</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>doy</name>
                    <field_number>24</field_number>
                    <field_location unit="byte">51</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag day of year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sec</name>
                    <field_number>25</field_number>
                    <field_location unit="byte">53</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Time tag seconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_day</name>
                    <field_number>26</field_number>
                    <field_location unit="byte">61</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Record creation time days.; Days since 1/1/1958.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_msec</name>
                    <field_number>27</field_number>
                    <field_location unit="byte">63</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Record creation time milliseconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_dss_id</name>
                    <field_number>28</field_number>
                    <field_location unit="byte">67</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink antenna number.  ;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_band</name>
                    <field_number>29</field_number>
                    <field_location unit="byte">68</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink frequency band.; 0 => Unknown; 1 => S-band; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_assembly_num</name>
                    <field_number>30</field_number>
                    <field_location unit="byte">69</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink Assembly Number.  ; Note that this is to allow for potential future cases where there might be more than one uplink of the same band at the same antenna.; 0 => Invalid/unknown; 1 => S-/X-band uplink; 2 => Ka-band uplink</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_num</name>
                    <field_number>31</field_number>
                    <field_location unit="byte">70</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter number.  ; Value depends on transmitter used.  A value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_stat</name>
                    <field_number>32</field_number>
                    <field_location unit="byte">71</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmit status.; 0 => Not transmitting out the horn; 1 => Transmitting out the horn; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_mode</name>
                    <field_number>33</field_number>
                    <field_location unit="byte">72</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter mode.; 0 => Low power; 1 => High power; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>cmd_modul_stat</name>
                    <field_number>34</field_number>
                    <field_location unit="byte">73</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Command modulation status.; 0 => OFF; 1 => ON; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rng_modul_stat</name>
                    <field_number>35</field_number>
                    <field_location unit="byte">74</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Ranging modulation status.; 0 => OFF; 1 => ON; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>fts_vld_flag</name>
                    <field_number>36</field_number>
                    <field_location unit="byte">75</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Frequency and Timing (FTS) validity.; 0 => Equipment is not synced with FTS; 1 => Equipment is synced with FTS</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1a</name>
                    <field_number>37</field_number>
                    <field_location unit="byte">76</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_time_tag_delay</name>
                    <field_number>38</field_number>
                    <field_location unit="byte">77</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Transmit time tag delay.  ; Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  Value of ?1.0 indicates invalid (or not provided).</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_zheight_corr</name>
                    <field_number>39</field_number>
                    <field_location unit="byte">85</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Uplink Z-height correction. ; Value of -99.0 indicates invalid.</description>
                    <Special_Constants>
                        <invalid_constant>-99.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_day</name>
                    <field_number>40</field_number>
                    <field_location unit="byte">89</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Modification time days.; Days since 1/1/1958.  Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_msec</name>
                    <field_number>41</field_number>
                    <field_location unit="byte">91</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Modification time milliseconds of day. ; Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>version_num</name>
                    <field_number>42</field_number>
                    <field_location unit="byte">95</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Version number.; Version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_version_num</name>
                    <field_number>43</field_number>
                    <field_location unit="byte">96</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-version number.; Sub-version number of the assembly that generated the data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_sub_version_num</name>
                    <field_number>44</field_number>
                    <field_location unit="byte">97</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-sub-version number.; Sub-sub-version number of the assembly that generated the data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1b</name>
                    <field_number>45</field_number>
                    <field_location unit="byte">98</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve4</name>
                    <field_number>46</field_number>
                    <field_location unit="byte">99</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Reserved.; Four bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>47</field_number>
                    <field_location unit="byte">103</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the uplink carrier phase data CHDO. ; CHDO contains binary data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>48</field_number>
                    <field_location unit="byte">105</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the uplink carrier phase data CHDO value field.; Number of bytes after this item.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_hi_phs_cycles</name>
                    <field_number>49</field_number>
                    <field_location unit="byte">107</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>High part phase data whole cycles.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_lo_phs_cycles</name>
                    <field_number>50</field_number>
                    <field_location unit="byte">111</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Low part phase data whole cycles.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_frac_phs_cycles</name>
                    <field_number>51</field_number>
                    <field_location unit="byte">115</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Fractional part phase data cycles.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ramp_freq</name>
                    <field_number>52</field_number>
                    <field_location unit="byte">119</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Sky level Hz at least 7.7 mHz precision (band dependent)</unit>
                    <description>Ramp frequency.  ; Precision varies with band (phase data gives higher precision).  A value of 0.0 indicates an invalid or unknown value; S-band => 0.5 mHz; X-band => 1.6 mHz ; Ka-band => 7.7 mHz</description>
                    <Special_Constants>
                        <invalid_constant>0.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>ramp_rate</name>
                    <field_number>53</field_number>
                    <field_location unit="byte">127</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Sky level Hz / sec</unit>
                    <description>Ramp rate.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_switch_stat</name>
                    <field_number>54</field_number>
                    <field_location unit="byte">135</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter switch status.; 0 => Antenna; 1 => Water load; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ramp_type</name>
                    <field_number>55</field_number>
                    <field_location unit="byte">136</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Ramp type.; 0 => Snap; 1 => Start of new ramp; 2 => Medial report; 3 => Periodic report; 4 => End of ramps; 5 => Ramping terminated by operator; 6 => Invalid/unknown; </description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_op_pwr</name>
                    <field_number>56</field_number>
                    <field_location unit="byte">137</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>W</unit>
                    <description>Transmitter output power.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sup_data_id</name>
                    <field_number>57</field_number>
                    <field_location unit="byte">141</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Support data ID.; Name of the frequency predicts set used.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sup_data_rev</name>
                    <field_number>58</field_number>
                    <field_location unit="byte">149</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Support data revision.; Revision of the frequency predicts set used.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>prdx_time_offset</name>
                    <field_number>59</field_number>
                    <field_location unit="byte">157</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Predicts time offset.; Seconds added to current time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>prdx_freq_offset</name>
                    <field_number>60</field_number>
                    <field_location unit="byte">165</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Hz</unit>
                    <description>Predicts frequency offset.; Hz added to predicted value.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>time_tag_corr_flag</name>
                    <field_number>61</field_number>
                    <field_location unit="byte">173</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Time tag correction flag.; Indicates results of validation of the block time tag.; 0 => No validation attempted; 1 => Validated, no change; 2 => Validated, changed</description>
                </Field_Binary>
                <Field_Binary>
                    <name>type_time_corr_flag</name>
                    <field_number>62</field_number>
                    <field_location unit="byte">174</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Type of time tag correction flag.; Indicates what type of time tag correction was made.; 0 => No correction; 1 => Year correction; 2 => DOY correction; 3 => Both Year and DOY correction</description>
                </Field_Binary>
                <Field_Binary>
                    <name>fabricated_sfdu_flag</name>
                    <field_number>63</field_number>
                    <field_location unit="byte">175</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Fabricated SFDU Flag; Indicates whether this SFDU was artificially fabricated in support of 3-way ranging.; 0 => Originally generated by UPL and validated by TTC software; 1 => Fabricated by TTC software</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1</name>
                    <field_number>64</field_number>
                    <field_location unit="byte">176</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve6</name>
                    <field_number>65</field_number>
                    <field_location unit="byte">177</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">6</field_length>
                    <description>Reserved.; Six bytes.</description>
                </Field_Binary>

            </Record_Binary>         
        </Table_Binary>

        <Table_Binary>
            <local_identifier>trk_TableBinary_SFDU_01</local_identifier>
            <offset unit="byte">6936020</offset>
            <records>30692</records>
            <Record_Binary>
                <fields>122</fields>
                <groups>0</groups>
                <record_length unit="byte">378</record_length>
                <Field_Binary>
                    <name>control_auth_id</name>
                    <field_number>1</field_number>
                    <field_location unit="byte">1</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Control authority identifier. ;  NJPL  indicates that the data description information for this SFDU is maintained and disseminated by NASA/JPL.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_version_id</name>
                    <field_number>2</field_number>
                    <field_location unit="byte">5</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU label version ID.;  2  indicates that the length attribute field in bytes 12 to 19 is formatted as a binary unsigned integer.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_class_id</name>
                    <field_number>3</field_number>
                    <field_location unit="byte">6</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU class ID.;  I  indicates that this SFDU contains data to be used by an application process.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>4</field_number>
                    <field_location unit="byte">7</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>data_description_id</name>
                    <field_number>5</field_number>
                    <field_location unit="byte">9</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Data description identifier.; Uniquely identifies the data description information held by the control authority identified in the  Control authority identifier  item for this type of SFDU.; C123 => Uplink types; C124 => Downlink types; C125 => Derived types; C126 => Interferometric types; C127 => Filtered types</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_length</name>
                    <field_number>6</field_number>
                    <field_location unit="byte">13</field_location>
                    <data_type>UnsignedMSB8</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the tracking data SFDU.; Indicates the length of the data following this element.; DT0 => 162; DT1 => 358 ; DT2 => 194 ; DT3 => 304 ; DT4 => 276 ; DT5 => 388 ; DT6 => 200; DT7 => 330; DT8 => 178 ; DT9 => 124; DT10 => 204 ; DT11 => 182; DT12 => 164 ; DT13 => 160; DT14 => 348; DT15 => 194; DT16 => 182 + 18 * num_obs; DT17 => 194 + 22 * num_obs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>7</field_number>
                    <field_location unit="byte">21</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the aggregation CHDO.; A value of 1 indicates that this CHDO is an aggregation of CHDOs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>8</field_number>
                    <field_location unit="byte">23</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the aggregation CHDO.; Indicates the length of the sum of the primary and secondary CHDOs.; CHDO 132 => 78; CHDO 133 => 122; CHDO 134 => 136; CHDO 135 => 100; CHDO 136 => 110</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>9</field_number>
                    <field_location unit="byte">25</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the primary CHDO.; A value of 2 indicates that this CHDO is a primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>10</field_number>
                    <field_location unit="byte">27</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the primary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mjr_data_class</name>
                    <field_number>11</field_number>
                    <field_location unit="byte">29</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Major data class.; A value of 6 indicates that the data in this SFDU is ground station monitor data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mnr_data_class</name>
                    <field_number>12</field_number>
                    <field_location unit="byte">30</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Minor data class.; Indicates data is processed tracking data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mission_id</name>
                    <field_number>13</field_number>
                    <field_location unit="byte">31</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Mission ID.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>format_code</name>
                    <field_number>14</field_number>
                    <field_location unit="byte">32</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Format code.; Also referred to as the data type.;   0  =>  Uplink Carrier Phase;   1  =>  Downlink Carrier Phase;   2  =>  Uplink Sequential Ranging Phase;   3  =>  Downlink Sequential Ranging Phase;   4  =>  Uplink PN Ranging Phase;   5  =>  Downlink PN Ranging Phase;   6  =>  Doppler;   7  =>  Sequential Ranging;   8  =>  Angles;   9  =>  Ramps ; 10  =>  VLBI; 11  =>  DRVID ; 12  =>  Smoothed Noise; 13  =>  Allan Deviation; 14  =>  PN Ranging; 15  =>  Tone Ranging; 16  =>  Carrier Observable; 17  =>  Total Phase Observable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>15</field_number>
                    <field_location unit="byte">33</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the secondary CHDO. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>16</field_number>
                    <field_location unit="byte">35</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the secondary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the secondary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>orig_id</name>
                    <field_number>17</field_number>
                    <field_location unit="byte">37</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Originator ID.; Indicates where this SFDU was originated. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>last_modifier_id</name>
                    <field_number>18</field_number>
                    <field_location unit="byte">38</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Last modifier ID.; Indicates where the contents of this SFDU were last modified. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1</name>
                    <field_number>19</field_number>
                    <field_location unit="byte">39</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.  ; For future expansion of scft_id.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_id</name>
                    <field_number>20</field_number>
                    <field_location unit="byte">40</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft number.;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dtt_rec_seq_num</name>
                    <field_number>21</field_number>
                    <field_location unit="byte">41</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Downlink Record sequence number (DTT RSN).; This is the record sequence number reported by the downlink subsystem (DTT) equipment. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>rec_seq_num</name>
                    <field_number>22</field_number>
                    <field_location unit="byte">45</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Record sequence number (RSN).; Begins with zero; increments by one for each successive downlink tracking SFDU of the same data type; wraps around from 232-1 to zero. Value is reset to zero when the data processing system software is restarted.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>year</name>
                    <field_number>23</field_number>
                    <field_location unit="byte">49</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>doy</name>
                    <field_number>24</field_number>
                    <field_location unit="byte">51</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag day of year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sec</name>
                    <field_number>25</field_number>
                    <field_location unit="byte">53</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Time tag seconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_day</name>
                    <field_number>26</field_number>
                    <field_location unit="byte">61</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Record creation time days.; Days since 1/1/1958.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_msec</name>
                    <field_number>27</field_number>
                    <field_location unit="byte">63</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Record creation time milliseconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_dss_id</name>
                    <field_number>28</field_number>
                    <field_location unit="byte">67</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Downlink antenna number.;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_band</name>
                    <field_number>29</field_number>
                    <field_location unit="byte">68</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Downlink frequency band.; 0 => Unknown; 1 => S-band; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_chan_num</name>
                    <field_number>30</field_number>
                    <field_location unit="byte">69</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Downlink channel number.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>prdx_mode</name>
                    <field_number>31</field_number>
                    <field_location unit="byte">70</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Predicts mode.; Predicts subset used by downlink channel.; 0 => No Predicts; 1 => One-way; 2 => Two-way; 3 => Three-way</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_prdx_stn</name>
                    <field_number>32</field_number>
                    <field_location unit="byte">71</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink station used for predicts.  ; Valid only if prdx_mode is 2 or 3. A value of 0 means that the number is unknown or not valid (e.g., no uplink).</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_band_dl</name>
                    <field_number>33</field_number>
                    <field_location unit="byte">72</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink frequency band assumed by downlink.; 0 => Unknown; 1 => S-band ; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band</description>
                </Field_Binary>
                <Field_Binary>
                    <name>array_delay</name>
                    <field_number>34</field_number>
                    <field_location unit="byte">73</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>seconds</unit>
                    <description>Array delay value.  ; Time delay added to path by arraying equipment.  Obtained from arraying equipment.  Any measurements include this delay.  Valid only if Array Flag (array_flag) is non-zero.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>fts_vld_flag</name>
                    <field_number>35</field_number>
                    <field_location unit="byte">81</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Frequency and Timing (FTS) validity.; 0 => Equipment is not synced with FTS; 1 => Equipment is synced with FTS</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_lock_stat</name>
                    <field_number>36</field_number>
                    <field_location unit="byte">82</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Carrier lock status.; 0 => Off; 1 => Open (only using predicts); 2 => Acquiring, FFT Search; 3 => Acquiring, Waiting for Lock Decision; 4 => In Lock; 5 => Out of Lock</description>
                </Field_Binary>
                <Field_Binary>
                    <name>array_flag</name>
                    <field_number>37</field_number>
                    <field_location unit="byte">83</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Array flag.; 0 => Not arrayed; 1 => Arrayed with FSP #1; 2 => Arrayed with FSP #2</description>
                </Field_Binary>
                <Field_Binary>
                    <name>polarization</name>
                    <field_number>38</field_number>
                    <field_location unit="byte">84</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Polarization.; 0 => RCP; 1 => LCP</description>
                </Field_Binary>
                <Field_Binary>
                    <name>diplxr_stat</name>
                    <field_number>39</field_number>
                    <field_location unit="byte">85</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Diplexer status.; 0 => Low noise; 1 => Diplexed</description>
                </Field_Binary>
                <Field_Binary>
                    <name>lna_num</name>
                    <field_number>40</field_number>
                    <field_location unit="byte">86</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>LNA Number.; Value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rf_if_chan_num</name>
                    <field_number>41</field_number>
                    <field_location unit="byte">87</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>RF-to-IF Downconverter Channel number.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>if_num</name>
                    <field_number>42</field_number>
                    <field_location unit="byte">88</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>IF input number.  ; Defines path into downlink channel.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rcv_time_tag_delay</name>
                    <field_number>43</field_number>
                    <field_location unit="byte">89</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>seconds</unit>
                    <description>Receive time tag delay.  ; Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  A value of -1.0 indicates invalid (or not provided).</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_zheight_corr</name>
                    <field_number>44</field_number>
                    <field_location unit="byte">97</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>seconds</unit>
                    <description>Downlink Z-height correction. ; Value of -99.0 indicates invalid.</description>
                    <Special_Constants>
                        <invalid_constant>-99.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_ul_stn</name>
                    <field_number>45</field_number>
                    <field_location unit="byte">101</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated uplink station.  ;  The uplink station per the validation process.  A value of 0 means that the antenna is unknown or not valid.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_dop_mode</name>
                    <field_number>46</field_number>
                    <field_location unit="byte">102</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated doppler mode.  ; 0 => Unknown or not applicable; 1 => One-way; 2 => Two-way; 3 => Three-way</description>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_scft_coh</name>
                    <field_number>47</field_number>
                    <field_location unit="byte">103</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated spacecraft coherency.  ; 0 => Unknown or not applicable; 1 => Coherent; 2 => Non-coherent; 3 => Transponded, non-coherent</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_lock</name>
                    <field_number>48</field_number>
                    <field_location unit="byte">104</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft transponder lock.; 0 => Unknown; 1 => Out-of-lock; 2 => In Lock</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_num</name>
                    <field_number>49</field_number>
                    <field_location unit="byte">105</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft transponder number.; 0 if unknown, transponder number otherwise.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1a</name>
                    <field_number>50</field_number>
                    <field_location unit="byte">106</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_osc_freq</name>
                    <field_number>51</field_number>
                    <field_location unit="byte">107</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Hz</unit>
                    <description>Spacecraft oscillator frequency.; Spacecraft one?way frequency.; 0.0 if unknown.</description>
                    <Special_Constants>
                        <unknown_constant>0.0</unknown_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_delay</name>
                    <field_number>52</field_number>
                    <field_location unit="byte">115</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Spacecraft transponder delay.  ; Coherent ranging delay.  Value of ?1.0 indicates invalid.</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_turn_num</name>
                    <field_number>53</field_number>
                    <field_location unit="byte">123</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Spacecraft transponder turn around ratio numerator.; A value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_turn_den</name>
                    <field_number>54</field_number>
                    <field_location unit="byte">127</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Spacecraft transponder turn around ratio denominator.; A value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_twnc_stat</name>
                    <field_number>55</field_number>
                    <field_location unit="byte">131</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft two-way non-coherent (TWNC) status.; 0 => Unknown; 1 => OFF; 2 => ON</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_osc_type</name>
                    <field_number>56</field_number>
                    <field_location unit="byte">132</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft oscillator type.; 0 => Unknown; 1 => AUX OSC (auxiliary oscillator); 2 => USO (ultra-stable oscillator)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_day</name>
                    <field_number>57</field_number>
                    <field_location unit="byte">133</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Modification time days.; Days since 1/1/1958.  Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_msec</name>
                    <field_number>58</field_number>
                    <field_location unit="byte">135</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Modification time milliseconds of day. ; Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>version_num</name>
                    <field_number>59</field_number>
                    <field_location unit="byte">139</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Version number.; Version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_version_num</name>
                    <field_number>60</field_number>
                    <field_location unit="byte">140</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-version number.; Sub-version number of the assembly that generated the data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_sub_version_num</name>
                    <field_number>61</field_number>
                    <field_location unit="byte">141</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-sub-version number.; Sub-sub-version number of the assembly that generated the data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>lna_corr_value</name>
                    <field_number>62</field_number>
                    <field_location unit="byte">142</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>LNA Correction Value.; Indicates results of validation of LNA number. Value of 0 indicates no validation or correction was made, otherwise if non-zero, this value is to be used instead of lna_num.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve4</name>
                    <field_number>63</field_number>
                    <field_location unit="byte">143</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Reserved.; Four bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>64</field_number>
                    <field_location unit="byte">147</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the downlink carrier phase data CHDO. ; CHDO contains binary data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>65</field_number>
                    <field_location unit="byte">149</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the downlink carrier phase data CHDO value field.; Number of bytes after this item.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_loop_bw</name>
                    <field_number>66</field_number>
                    <field_location unit="byte">151</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Hz</unit>
                    <description>Carrier tracking loop bandwidth.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>pcn0</name>
                    <field_number>67</field_number>
                    <field_location unit="byte">155</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>dB-Hz</unit>
                    <description>Pc/N0.; Carrier power to noise spectral density ratio.  Has a value of -300.0 if no signal.</description>
                    <Special_Constants>
                        <not_applicable_constant>-300.0</not_applicable_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>pcn0_resid</name>
                    <field_number>68</field_number>
                    <field_location unit="byte">159</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>dB-Hz</unit>
                    <description>Pc/N0 residual.; Actual value minus predicted value.</description>
                    <Special_Constants>
                        <not_applicable_constant>-300.0</not_applicable_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>pdn0</name>
                    <field_number>69</field_number>
                    <field_location unit="byte">163</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>dB-Hz</unit>
                    <description>Pd/N0.; Data power to noise spectral density ratio.  Has a value of -300.0 if no signal.</description>
                    <Special_Constants>
                        <not_applicable_constant>-300.0</not_applicable_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>pdn0_resid</name>
                    <field_number>70</field_number>
                    <field_location unit="byte">167</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>dB-Hz</unit>
                    <description>Pd/N0 residual.; Actual value minus predicted value.</description>
                    <Special_Constants>
                        <not_applicable_constant>-300.0</not_applicable_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>system_noise_temp</name>
                    <field_number>71</field_number>
                    <field_location unit="byte">171</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>k (degrees kelvin)</unit>
                    <description>System Noise Temperature.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_0</name>
                    <field_number>72</field_number>
                    <field_location unit="byte">175</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 0   High part phase data whole cycles.; (time tag + 0.0 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_0</name>
                    <field_number>73</field_number>
                    <field_location unit="byte">179</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 0   Low part phase data whole cycles.; (time tag + 0.0 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_0</name>
                    <field_number>74</field_number>
                    <field_location unit="byte">183</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 0   Fractional part phase data cycles.; (time tag + 0.0 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_1</name>
                    <field_number>75</field_number>
                    <field_location unit="byte">187</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 1   High part phase data whole cycles.; (time tag + 0.1 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_1</name>
                    <field_number>76</field_number>
                    <field_location unit="byte">191</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 1   Low part phase data whole cycles.; (time tag + 0.1 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_1</name>
                    <field_number>77</field_number>
                    <field_location unit="byte">195</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 1   Fractional part phase data cycles.; (time tag + 0.1 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_2</name>
                    <field_number>78</field_number>
                    <field_location unit="byte">199</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 2   High part phase data whole cycles.; (time tag + 0.2 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_2</name>
                    <field_number>79</field_number>
                    <field_location unit="byte">203</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 2   Low part phase data whole cycles.; (time tag + 0.2 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_2</name>
                    <field_number>80</field_number>
                    <field_location unit="byte">207</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 2   Fractional part phase data cycles.; (time tag + 0.2 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_3</name>
                    <field_number>81</field_number>
                    <field_location unit="byte">211</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 3   High part phase data whole cycles.; (time tag + 0.3 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_3</name>
                    <field_number>82</field_number>
                    <field_location unit="byte">215</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 3   Low part phase data whole cycles.; (time tag + 0.3 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_3</name>
                    <field_number>83</field_number>
                    <field_location unit="byte">219</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 3   Fractional part phase data cycles.; (time tag + 0.3 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_4</name>
                    <field_number>84</field_number>
                    <field_location unit="byte">223</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 4   High part phase data whole cycles.; (time tag + 0.4 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_4</name>
                    <field_number>85</field_number>
                    <field_location unit="byte">227</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 4   Low part phase data whole cycles.; (time tag + 0.4 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_4</name>
                    <field_number>86</field_number>
                    <field_location unit="byte">231</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 4   Fractional part phase data cycles.; (time tag + 0.4 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_5</name>
                    <field_number>87</field_number>
                    <field_location unit="byte">235</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 5   High part phase data whole cycles.; (time tag + 0.5 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_5</name>
                    <field_number>88</field_number>
                    <field_location unit="byte">239</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 5   Low part phase data whole cycles.; (time tag + 0.5 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_5</name>
                    <field_number>89</field_number>
                    <field_location unit="byte">243</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 5   Fractional part phase data cycles.; (time tag + 0.5 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_6</name>
                    <field_number>90</field_number>
                    <field_location unit="byte">247</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 6   High part phase data whole cycles.; (time tag + 0.6 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_6</name>
                    <field_number>91</field_number>
                    <field_location unit="byte">251</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 6   Low part phase data whole cycles.; (time tag + 0.6 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_6</name>
                    <field_number>92</field_number>
                    <field_location unit="byte">255</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 6   Fractional part phase data cycles.; (time tag + 0.6 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_7</name>
                    <field_number>93</field_number>
                    <field_location unit="byte">259</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 7   High part phase data whole cycles.; (time tag + 0.7 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_7</name>
                    <field_number>94</field_number>
                    <field_location unit="byte">263</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 7   Low part phase data whole cycles.; (time tag + 0.7 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_7</name>
                    <field_number>95</field_number>
                    <field_location unit="byte">267</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 7   Fractional part phase data cycles; (time tag + 0.7 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_8</name>
                    <field_number>96</field_number>
                    <field_location unit="byte">271</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 8   High part phase data whole cycles.; (time tag + 0.8 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_8</name>
                    <field_number>97</field_number>
                    <field_location unit="byte">275</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 8   Low part phase data whole cycles.; (time tag + 0.8 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_8</name>
                    <field_number>98</field_number>
                    <field_location unit="byte">279</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 8   Fractional part phase data cycles.; (time tag + 0.8 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_9</name>
                    <field_number>99</field_number>
                    <field_location unit="byte">283</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Raw phase sample 9   High part phase data whole cycles.; (time tag + 0.9 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_9</name>
                    <field_number>100</field_number>
                    <field_location unit="byte">287</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Raw phase sample 9   Low part phase data whole cycles.; (time tag + 0.9 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_9</name>
                    <field_number>101</field_number>
                    <field_location unit="byte">291</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Raw phase sample 9   Fractional part phase data cycles.; (time tag + 0.9 sec)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_hi_avg</name>
                    <field_number>102</field_number>
                    <field_location unit="byte">295</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Averaged phase sample   High part phase data whole cycles.; One-second average, centered around time tag.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_lo_avg</name>
                    <field_number>103</field_number>
                    <field_location unit="byte">299</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Averaged phase sample   Low part phase data whole cycles.; One-second average, centered around time tag.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>phs_frac_avg</name>
                    <field_number>104</field_number>
                    <field_location unit="byte">303</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Averaged phase sample   Fractional part phase data cycles.; One-second average, centered around time tag.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_freq</name>
                    <field_number>105</field_number>
                    <field_location unit="byte">307</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Sky level Hz</unit>
                    <description>Downlink frequency. ; Frequency at the time tag.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dop_resid</name>
                    <field_number>106</field_number>
                    <field_location unit="byte">315</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Sky level Hz</unit>
                    <description>Doppler residual. ; Negative of frequency residual.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dop_noise</name>
                    <field_number>107</field_number>
                    <field_location unit="byte">319</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Hz</unit>
                    <description>Doppler noise.  ; Averaged over 10 points in record.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>slipped_cycles</name>
                    <field_number>108</field_number>
                    <field_location unit="byte">323</field_location>
                    <data_type>SignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Slipped cycles.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_loop_type</name>
                    <field_number>109</field_number>
                    <field_location unit="byte">327</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Carrier loop type.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>snt_flag</name>
                    <field_number>110</field_number>
                    <field_location unit="byte">328</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SNT measurement flag.; 0 => SNT value is the predicted value; 1 => SNT value is the measured value</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_resid_wt</name>
                    <field_number>111</field_number>
                    <field_location unit="byte">329</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Carrier residual weight.; (Weight value applied to residual phase error in carrier tracking; suppressed carrier weight is 1.0 minus this value.)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sup_data_id</name>
                    <field_number>112</field_number>
                    <field_location unit="byte">333</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Support data ID.; Name of the frequency predicts set used.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sup_data_rev</name>
                    <field_number>113</field_number>
                    <field_location unit="byte">341</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Support data revision.; Revision of the frequency predicts set used.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>prdx_time_offset</name>
                    <field_number>114</field_number>
                    <field_location unit="byte">349</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Predicts time offset.; Seconds added to current time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>prdx_freq_offset</name>
                    <field_number>115</field_number>
                    <field_location unit="byte">357</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Hz</unit>
                    <description>Predicts frequency offset. ; Hz added to predicted value.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_resid_tol_flag</name>
                    <field_number>116</field_number>
                    <field_location unit="byte">365</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Carrier residual tolerance flag.; 0 => Out of tolerance; 1 => In tolerance</description>
                </Field_Binary>
                <Field_Binary>
                    <name>time_tag_corr_flag</name>
                    <field_number>117</field_number>
                    <field_location unit="byte">366</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Time tag correction flag.; Indicates results of validation of the block time tag.; 0 => No validation attempted; 1 => Validated, no change; 2 => Validated, changed</description>
                </Field_Binary>
                <Field_Binary>
                    <name>type_time_corr_flag</name>
                    <field_number>118</field_number>
                    <field_location unit="byte">367</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Type of time tag correction flag.; Indicates what type of time tag correction was made.; 0 => No correction; 1 => Year correction; 2 => DOY correction; 3 => Both Year and DOY correction</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dop_mode_corr_flag</name>
                    <field_number>119</field_number>
                    <field_location unit="byte">368</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Doppler mode correction flag.; Indicates the results of the validation of the doppler mode.; 0 => Not applicable or no validation attempted; 1 => Validated, no change; 2 => Validated, changed</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_stn_corr_flag</name>
                    <field_number>120</field_number>
                    <field_location unit="byte">369</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink station correction flag.; Indicates the results of the validation of the uplink station.; 0 => Not applicable or no validation attempted; 1 => Validated, no change; 2 => Validated, changed</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1</name>
                    <field_number>121</field_number>
                    <field_location unit="byte">370</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve8</name>
                    <field_number>122</field_number>
                    <field_location unit="byte">371</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Reserved.; Eight bytes.</description>
                </Field_Binary>

            </Record_Binary>         
        </Table_Binary>

        <Table_Binary>
            <local_identifier>trk_TableBinary_SFDU_09</local_identifier>
            <offset unit="byte">18537596</offset>
            <records>10</records>
            <Record_Binary>
                <fields>56</fields>
                <groups>0</groups>
                <record_length unit="byte">144</record_length>
                <Field_Binary>
                    <name>control_auth_id</name>
                    <field_number>1</field_number>
                    <field_location unit="byte">1</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Control authority identifier. ;  NJPL  indicates that the data description information for this SFDU is maintained and disseminated by NASA/JPL.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_version_id</name>
                    <field_number>2</field_number>
                    <field_location unit="byte">5</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU label version ID.;  2  indicates that the length attribute field in bytes 12 to 19 is formatted as a binary unsigned integer.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_class_id</name>
                    <field_number>3</field_number>
                    <field_location unit="byte">6</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU class ID.;  I  indicates that this SFDU contains data to be used by an application process.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>4</field_number>
                    <field_location unit="byte">7</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>data_description_id</name>
                    <field_number>5</field_number>
                    <field_location unit="byte">9</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Data description identifier.; Uniquely identifies the data description information held by the control authority identified in the  Control authority identifier  item for this type of SFDU.; C123 => Uplink types; C124 => Downlink types; C125 => Derived types; C126 => Interferometric types; C127 => Filtered types</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_length</name>
                    <field_number>6</field_number>
                    <field_location unit="byte">13</field_location>
                    <data_type>UnsignedMSB8</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the tracking data SFDU.; Indicates the length of the data following this element.; DT0 => 162; DT1 => 358 ; DT2 => 194 ; DT3 => 304 ; DT4 => 276 ; DT5 => 388 ; DT6 => 200; DT7 => 330; DT8 => 178 ; DT9 => 124; DT10 => 204 ; DT11 => 182; DT12 => 164 ; DT13 => 160; DT14 => 348; DT15 => 194; DT16 => 182 + 18 * num_obs; DT17 => 194 + 22 * num_obs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>7</field_number>
                    <field_location unit="byte">21</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the aggregation CHDO.; A value of 1 indicates that this CHDO is an aggregation of CHDOs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>8</field_number>
                    <field_location unit="byte">23</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the aggregation CHDO.; Indicates the length of the sum of the primary and secondary CHDOs.; CHDO 132 => 78; CHDO 133 => 122; CHDO 134 => 136; CHDO 135 => 100; CHDO 136 => 110</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>9</field_number>
                    <field_location unit="byte">25</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the primary CHDO.; A value of 2 indicates that this CHDO is a primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>10</field_number>
                    <field_location unit="byte">27</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the primary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mjr_data_class</name>
                    <field_number>11</field_number>
                    <field_location unit="byte">29</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Major data class.; A value of 6 indicates that the data in this SFDU is ground station monitor data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mnr_data_class</name>
                    <field_number>12</field_number>
                    <field_location unit="byte">30</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Minor data class.; Indicates data is processed tracking data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mission_id</name>
                    <field_number>13</field_number>
                    <field_location unit="byte">31</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Mission ID.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>format_code</name>
                    <field_number>14</field_number>
                    <field_location unit="byte">32</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Format code.; Also referred to as the data type.;   0  =>  Uplink Carrier Phase;   1  =>  Downlink Carrier Phase;   2  =>  Uplink Sequential Ranging Phase;   3  =>  Downlink Sequential Ranging Phase;   4  =>  Uplink PN Ranging Phase;   5  =>  Downlink PN Ranging Phase;   6  =>  Doppler;   7  =>  Sequential Ranging;   8  =>  Angles;   9  =>  Ramps ; 10  =>  VLBI; 11  =>  DRVID ; 12  =>  Smoothed Noise; 13  =>  Allan Deviation; 14  =>  PN Ranging; 15  =>  Tone Ranging; 16  =>  Carrier Observable; 17  =>  Total Phase Observable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>15</field_number>
                    <field_location unit="byte">33</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the secondary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>16</field_number>
                    <field_location unit="byte">35</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the secondary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the secondary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>orig_id</name>
                    <field_number>17</field_number>
                    <field_location unit="byte">37</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Originator ID.; Indicates where this SFDU was originated. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>last_modifier_id</name>
                    <field_number>18</field_number>
                    <field_location unit="byte">38</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Last modifier ID.; Indicates where the contents of this SFDU were last modified. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1</name>
                    <field_number>19</field_number>
                    <field_location unit="byte">39</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.  ; For future expansion of scft_id.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_id</name>
                    <field_number>20</field_number>
                    <field_location unit="byte">40</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft number.;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>upl_rec_seq_num</name>
                    <field_number>21</field_number>
                    <field_location unit="byte">41</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Uplink record sequence number (UPL RSN).; This is the record sequence number reported by the uplink subsystem (UPL) equipment.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rec_seq_num</name>
                    <field_number>22</field_number>
                    <field_location unit="byte">45</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Record sequence number (RSN).; Begins with zero; increments by one for each successive uplink tracking SFDU of the same data type; wraps around from 232-1 to zero. Value is reset to zero when the data processing system software is restarted.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>year</name>
                    <field_number>23</field_number>
                    <field_location unit="byte">49</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>doy</name>
                    <field_number>24</field_number>
                    <field_location unit="byte">51</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag day of year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sec</name>
                    <field_number>25</field_number>
                    <field_location unit="byte">53</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Time tag seconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_day</name>
                    <field_number>26</field_number>
                    <field_location unit="byte">61</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Record creation time days.; Days since 1/1/1958.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_msec</name>
                    <field_number>27</field_number>
                    <field_location unit="byte">63</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Record creation time milliseconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_dss_id</name>
                    <field_number>28</field_number>
                    <field_location unit="byte">67</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink antenna number.  ;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_band</name>
                    <field_number>29</field_number>
                    <field_location unit="byte">68</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink frequency band.; 0 => Unknown; 1 => S-band; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_assembly_num</name>
                    <field_number>30</field_number>
                    <field_location unit="byte">69</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink Assembly Number.  ; Note that this is to allow for potential future cases where there might be more than one uplink of the same band at the same antenna.; 0 => Invalid/unknown; 1 => S-/X-band uplink; 2 => Ka-band uplink</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_num</name>
                    <field_number>31</field_number>
                    <field_location unit="byte">70</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter number.  ; Value depends on transmitter used.  A value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_stat</name>
                    <field_number>32</field_number>
                    <field_location unit="byte">71</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmit status.; 0 => Not transmitting out the horn; 1 => Transmitting out the horn; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_mode</name>
                    <field_number>33</field_number>
                    <field_location unit="byte">72</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter mode.; 0 => Low power; 1 => High power; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>cmd_modul_stat</name>
                    <field_number>34</field_number>
                    <field_location unit="byte">73</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Command modulation status.; 0 => OFF; 1 => ON; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rng_modul_stat</name>
                    <field_number>35</field_number>
                    <field_location unit="byte">74</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Ranging modulation status.; 0 => OFF; 1 => ON; 2 => Invalid/unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>fts_vld_flag</name>
                    <field_number>36</field_number>
                    <field_location unit="byte">75</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Frequency and Timing (FTS) validity.; 0 => Equipment is not synced with FTS; 1 => Equipment is synced with FTS</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1a</name>
                    <field_number>37</field_number>
                    <field_location unit="byte">76</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_time_tag_delay</name>
                    <field_number>38</field_number>
                    <field_location unit="byte">77</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Transmit time tag delay.  ; Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  Value of ?1.0 indicates invalid (or not provided).</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_zheight_corr</name>
                    <field_number>39</field_number>
                    <field_location unit="byte">85</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Uplink Z-height correction. ; Value of -99.0 indicates invalid.</description>
                    <Special_Constants>
                        <invalid_constant>-99.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_day</name>
                    <field_number>40</field_number>
                    <field_location unit="byte">89</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Modification time days.; Days since 1/1/1958.  Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_msec</name>
                    <field_number>41</field_number>
                    <field_location unit="byte">91</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Modification time milliseconds of day. ; Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>version_num</name>
                    <field_number>42</field_number>
                    <field_location unit="byte">95</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Version number.; Version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_version_num</name>
                    <field_number>43</field_number>
                    <field_location unit="byte">96</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-version number.; Sub-version number of the assembly that generated the data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_sub_version_num</name>
                    <field_number>44</field_number>
                    <field_location unit="byte">97</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-sub-version number.; Sub-sub-version number of the assembly that generated the data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1b</name>
                    <field_number>45</field_number>
                    <field_location unit="byte">98</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve4</name>
                    <field_number>46</field_number>
                    <field_location unit="byte">99</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Reserved.; Four bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>47</field_number>
                    <field_location unit="byte">103</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the ramp data CHDO. ; CHDO contains binary data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>48</field_number>
                    <field_location unit="byte">105</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the ramp data CHDO value field. Number of bytes after this item.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_hi_phs_cycles</name>
                    <field_number>49</field_number>
                    <field_location unit="byte">107</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>High part uplink phase data whole cycles.; Phase at time tag.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_lo_phs_cycles</name>
                    <field_number>50</field_number>
                    <field_location unit="byte">111</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Low part uplink phase data whole cycles.; Phase at time tag.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_frac_phs_cycles</name>
                    <field_number>51</field_number>
                    <field_location unit="byte">115</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Fractional part uplink phase data cycles.; Phase at time tag.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ramp_freq</name>
                    <field_number>52</field_number>
                    <field_location unit="byte">119</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Sky level Hz at least 7.7 mHz precision (band dependent)</unit>
                    <description>Ramp frequency.  ; Precision varies with band (phase data gives higher precision).  A value of 0.0 indicates an invalid or unknown value.; S-band => 0.5 mHz; X-band => 1.6 mHz ; Ka-band => 7.7 mHz</description>
                    <Special_Constants>
                        <invalid_constant>0.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>ramp_rate</name>
                    <field_number>53</field_number>
                    <field_location unit="byte">127</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Sky level Hz / sec</unit>
                    <description>Ramp rate.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ramp_type</name>
                    <field_number>54</field_number>
                    <field_location unit="byte">135</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Ramp type.; 0 => Snap; 1 => Start of new ramp; 2 => Medial report; 3 => Periodic report; 4 => End of ramps; 5 => Ramping terminated by operator; 6 => Invalid/unknown; </description>
                </Field_Binary>
                <Field_Binary>
                    <name>fabricated_sfdu_flag</name>
                    <field_number>55</field_number>
                    <field_location unit="byte">136</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Fabricated SFDU Flag; Indicates whether this SFDU was artificially fabricated in support of 3-way ranging.; 0 => Originally generated by UPL and validated by TTC software; 1 => Fabricated by TTC software</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve8</name>
                    <field_number>56</field_number>
                    <field_location unit="byte">137</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Reserved.; Eight bytes.</description>
                </Field_Binary>

            </Record_Binary>         
        </Table_Binary>

        <Table_Binary>
            <local_identifier>trk_TableBinary_SFDU_16</local_identifier>
            <offset unit="byte">18539036</offset>
            <records>30689</records>
            <Record_Binary>
                <fields>86</fields>
                <groups>0</groups>
                <record_length unit="byte">220</record_length>
                <Field_Binary>
                    <name>control_auth_id</name>
                    <field_number>1</field_number>
                    <field_location unit="byte">1</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Control authority identifier. ;  NJPL  indicates that the data description information for this SFDU is maintained and disseminated by NASA/JPL.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_version_id</name>
                    <field_number>2</field_number>
                    <field_location unit="byte">5</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU label version ID.;  2  indicates that the length attribute field in bytes 12 to 19 is formatted as a binary unsigned integer.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_class_id</name>
                    <field_number>3</field_number>
                    <field_location unit="byte">6</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU class ID.;  I  indicates that this SFDU contains data to be used by an application process.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>4</field_number>
                    <field_location unit="byte">7</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>data_description_id</name>
                    <field_number>5</field_number>
                    <field_location unit="byte">9</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Data description identifier.; Uniquely identifies the data description information held by the control authority identified in the  Control authority identifier  item for this type of SFDU.; C123 => Uplink types; C124 => Downlink types; C125 => Derived types; C126 => Interferometric types; C127 => Filtered types</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_length</name>
                    <field_number>6</field_number>
                    <field_location unit="byte">13</field_location>
                    <data_type>UnsignedMSB8</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the tracking data SFDU.; Indicates the length of the data following this element.; DT0 => 162; DT1 => 358 ; DT2 => 194 ; DT3 => 304 ; DT4 => 276 ; DT5 => 388 ; DT6 => 200; DT7 => 330; DT8 => 178 ; DT9 => 124; DT10 => 204 ; DT11 => 182; DT12 => 164 ; DT13 => 160; DT14 => 348; DT15 => 194; DT16 => 182 + 18 * num_obs; DT17 => 194 + 22 * num_obs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>7</field_number>
                    <field_location unit="byte">21</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the aggregation CHDO.; A value of 1 indicates that this CHDO is an aggregation of CHDOs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>8</field_number>
                    <field_location unit="byte">23</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the aggregation CHDO.; Indicates the length of the sum of the primary and secondary CHDOs.; CHDO 132 => 78; CHDO 133 => 122; CHDO 134 => 136; CHDO 135 => 100; CHDO 136 => 110</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>9</field_number>
                    <field_location unit="byte">25</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the primary CHDO.; A value of 2 indicates that this CHDO is a primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>10</field_number>
                    <field_location unit="byte">27</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the primary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mjr_data_class</name>
                    <field_number>11</field_number>
                    <field_location unit="byte">29</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Major data class.; A value of 6 indicates that the data in this SFDU is ground station monitor data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mnr_data_class</name>
                    <field_number>12</field_number>
                    <field_location unit="byte">30</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Minor data class.; Indicates data is processed tracking data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mission_id</name>
                    <field_number>13</field_number>
                    <field_location unit="byte">31</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Mission ID.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>format_code</name>
                    <field_number>14</field_number>
                    <field_location unit="byte">32</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Format code.; Also referred to as the data type.;   0  =>  Uplink Carrier Phase;   1  =>  Downlink Carrier Phase;   2  =>  Uplink Sequential Ranging Phase;   3  =>  Downlink Sequential Ranging Phase;   4  =>  Uplink PN Ranging Phase;   5  =>  Downlink PN Ranging Phase;   6  =>  Doppler;   7  =>  Sequential Ranging;   8  =>  Angles;   9  =>  Ramps ; 10  =>  VLBI; 11  =>  DRVID ; 12  =>  Smoothed Noise; 13  =>  Allan Deviation; 14  =>  PN Ranging; 15  =>  Tone Ranging; 16  =>  Carrier Observable; 17  =>  Total Phase Observable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>15</field_number>
                    <field_location unit="byte">33</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the secondary CHDO. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>16</field_number>
                    <field_location unit="byte">35</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the secondary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the secondary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>orig_id</name>
                    <field_number>17</field_number>
                    <field_location unit="byte">37</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Originator ID.; Indicates where this SFDU was originated. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>last_modifier_id</name>
                    <field_number>18</field_number>
                    <field_location unit="byte">38</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Last modifier ID.; Indicates where this SFDU was last modified. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1</name>
                    <field_number>19</field_number>
                    <field_location unit="byte">39</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.  ; For future expansion of scft_id.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_id</name>
                    <field_number>20</field_number>
                    <field_location unit="byte">40</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft number.;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rec_seq_num</name>
                    <field_number>21</field_number>
                    <field_location unit="byte">41</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Record sequence number (RSN).; Begins with zero; increments by one for each successive tracking SFDU of the same type; wraps around from 232-1 to zero. Value is reset to zero when software is restarted.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>year</name>
                    <field_number>22</field_number>
                    <field_location unit="byte">45</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>doy</name>
                    <field_number>23</field_number>
                    <field_location unit="byte">47</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag day of year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sec</name>
                    <field_number>24</field_number>
                    <field_location unit="byte">49</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Time tag seconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_day</name>
                    <field_number>25</field_number>
                    <field_location unit="byte">57</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Record creation time days.; Days since 1/1/1958.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_msec</name>
                    <field_number>26</field_number>
                    <field_location unit="byte">59</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Record creation time milliseconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>stn_stream_src</name>
                    <field_number>27</field_number>
                    <field_location unit="byte">63</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Station stream source.; 1 => UPL/DTT ; 2 => non-UPL-DTT: TRK?2?30; 3 => non-UPL-DTT: TRK?2?20</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_band</name>
                    <field_number>28</field_number>
                    <field_location unit="byte">64</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink frequency band.; 0 => Unknown or not applicable; 1 => S-band; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_assembly_num</name>
                    <field_number>29</field_number>
                    <field_location unit="byte">65</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink Assembly Number.  ; Note that this is to allow for potential future cases where there might be more than one uplink of the same band at the same antenna.; 0 => Unknown/Not applicable; 1 => S-/X-band uplink; 2 => Ka-band uplink</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_num</name>
                    <field_number>30</field_number>
                    <field_location unit="byte">66</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter number.  ; Value depends on transmitter used. A value of 0 means that the number is unknown or not applicable.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_stat</name>
                    <field_number>31</field_number>
                    <field_location unit="byte">67</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmit Status.; 0 => Not transmitting out the horn; 1 => Transmitting out the horn; 2 => Invalid or unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_mode</name>
                    <field_number>32</field_number>
                    <field_location unit="byte">68</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter mode.; 0 => Low power; 1 => High power; 2 => Invalid or unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>cmd_modul_stat</name>
                    <field_number>33</field_number>
                    <field_location unit="byte">69</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Command modulation status.; 0 => OFF; 1 => ON; 2 => Invalid or unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rng_modul_stat</name>
                    <field_number>34</field_number>
                    <field_location unit="byte">70</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Ranging modulation status.; 0 => OFF; 1 => ON; 2 => Invalid or unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_time_tag_delay</name>
                    <field_number>35</field_number>
                    <field_location unit="byte">71</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Transmit time tag delay.  ; Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  A value of -1.0 indicates invalid (or not provided).</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_zheight_corr</name>
                    <field_number>36</field_number>
                    <field_location unit="byte">79</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Uplink Z-height correction.; Value of -99.0 indicates invalid.</description>
                    <Special_Constants>
                        <invalid_constant>-99.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_dss_id</name>
                    <field_number>37</field_number>
                    <field_location unit="byte">83</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Downlink antenna number.;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1a</name>
                    <field_number>38</field_number>
                    <field_location unit="byte">84</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_chan_num</name>
                    <field_number>39</field_number>
                    <field_location unit="byte">85</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Downlink channel number.; Value of 0 implies unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>prdx_mode</name>
                    <field_number>40</field_number>
                    <field_location unit="byte">86</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Predicts mode.; Predicts subset used by downlink channel.; 0 => No Predicts; 1 => One-way; 2 => Two-way; 3 => Three-way; 4 => Unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_prdx_stn</name>
                    <field_number>41</field_number>
                    <field_location unit="byte">87</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink station used for predicts.; Valid only if prdx_mode is 2 or 3. A value of 0 means that the number is unknown or not valid (e.g., no uplink).</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_band_dl</name>
                    <field_number>42</field_number>
                    <field_location unit="byte">88</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink frequency band assumed by downlink.; Uplink band value used by downlink for turn around computations.; 0 => Unknown or not applicable; 1 => S-band ; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band</description>
                </Field_Binary>
                <Field_Binary>
                    <name>array_delay</name>
                    <field_number>43</field_number>
                    <field_location unit="byte">89</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Array delay value.  ; Time delay added to path by arraying equipment.  Obtained from arraying equipment.  Any measurements include this delay.  Valid only if Array Flag  (array_flag) is non-zero.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>fts_vld_flag</name>
                    <field_number>44</field_number>
                    <field_location unit="byte">97</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Frequency and Timing (FTS) validity.; 0 => Equipment is not synced with FTS; 1 => Equipment is synced with FTS</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_lock_stat</name>
                    <field_number>45</field_number>
                    <field_location unit="byte">98</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Carrier lock status.; 0 => Off; 1 => Open (using only predicts); 2 => Acquiring, FFT Search; 3 => Acquiring, Waiting for Lock Decision; 4 => In Lock; 5 => Out of Lock</description>
                </Field_Binary>
                <Field_Binary>
                    <name>array_flag</name>
                    <field_number>46</field_number>
                    <field_location unit="byte">99</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Array flag.; 0 => Non-arrayed; 1 => Arrayed with FSP #1; 2 => Arrayed with FSP #2</description>
                </Field_Binary>
                <Field_Binary>
                    <name>lna_num</name>
                    <field_number>47</field_number>
                    <field_location unit="byte">100</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>LNA Number.; Value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rcv_time_tag_delay</name>
                    <field_number>48</field_number>
                    <field_location unit="byte">101</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Receive time tag delay.  ; Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  A value of -1.0 indicates invalid (or not provided).</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_zheight_corr</name>
                    <field_number>49</field_number>
                    <field_location unit="byte">109</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Downlink Z-height correction.; Value of -99.0 indicates invalid. </description>
                    <Special_Constants>
                        <invalid_constant>-99.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_ul_stn</name>
                    <field_number>50</field_number>
                    <field_location unit="byte">113</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated uplink station.  ;  The uplink station per the validation process.  A value of 0 means that the antenna is unknown or not valid.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_dop_mode</name>
                    <field_number>51</field_number>
                    <field_location unit="byte">114</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated doppler mode.  ; 0 => Unknown or not applicable; 1 => One-way; 2 => Two-way; 3 => Three-way</description>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_scft_coh</name>
                    <field_number>52</field_number>
                    <field_location unit="byte">115</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated spacecraft coherency.  ; 0 => Unknown or not applicable; 1 => Coherent; 2 => Non-coherent; 3 => Transponded, non-coherent</description>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_dl_band</name>
                    <field_number>53</field_number>
                    <field_location unit="byte">116</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated downlink frequency band.; 0 => Unknown; 1 => S-band; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band; 6 => S or X band (26m stations)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_lock</name>
                    <field_number>54</field_number>
                    <field_location unit="byte">117</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft transponder lock.; 0 => Unknown; 1 => Out-of-lock; 2 => In Lock</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_num</name>
                    <field_number>55</field_number>
                    <field_location unit="byte">118</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft transponder number.; 0 if unknown, transponder number otherwise.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>56</field_number>
                    <field_location unit="byte">119</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_osc_freq</name>
                    <field_number>57</field_number>
                    <field_location unit="byte">121</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Hz</unit>
                    <description>Spacecraft oscillator frequency.; Spacecraft one?way frequency.  0.0 if unknown.</description>
                    <Special_Constants>
                        <unknown_constant>0.0</unknown_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_delay</name>
                    <field_number>58</field_number>
                    <field_location unit="byte">129</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Spacecraft transponder delay.; Coherent ranging delay.  Value of ?1.0 indicates invalid.</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_turn_num</name>
                    <field_number>59</field_number>
                    <field_location unit="byte">137</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Spacecraft transponder turn around ratio numerator.; A value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_turn_den</name>
                    <field_number>60</field_number>
                    <field_location unit="byte">141</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Spacecraft transponder turn around ratio denominator.; A value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_twnc_stat</name>
                    <field_number>61</field_number>
                    <field_location unit="byte">145</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft two-way non-coherent (TWNC) status.; 0 => Unknown; 1 => OFF; 2 => ON</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_osc_type</name>
                    <field_number>62</field_number>
                    <field_location unit="byte">146</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft oscillator type.; 0 => Unknown; 1 => AUX OSC (auxiliary oscillator); 2 => USO (ultra-stable oscillator)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_day</name>
                    <field_number>63</field_number>
                    <field_location unit="byte">147</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Modification time days.; Days since 1/1/1958.  Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_msec</name>
                    <field_number>64</field_number>
                    <field_location unit="byte">149</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Modification time milliseconds of day. ; Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>cnt_time</name>
                    <field_number>65</field_number>
                    <field_location unit="byte">153</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Count time.; Integration time of the counts.  Value of 0 indicates Not Applicable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>version_num</name>
                    <field_number>66</field_number>
                    <field_location unit="byte">157</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Version number.; Version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_version_num</name>
                    <field_number>67</field_number>
                    <field_location unit="byte">158</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-version number.; Sub-version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_sub_version_num</name>
                    <field_number>68</field_number>
                    <field_location unit="byte">159</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-sub-version number.; Sub-sub-version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>lna_corr_value</name>
                    <field_number>69</field_number>
                    <field_location unit="byte">160</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>LNA Correction Value.; Indicates results of validation of LNA number.; Value of 0 indicates no validation or correction was made, otherwise if non-zero, this value is to be used instead of lna_num .</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>70</field_number>
                    <field_location unit="byte">161</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the Carrier Frequency Observables data CHDO.; CHDO contains binary data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>71</field_number>
                    <field_location unit="byte">163</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the Carrier Frequency Observables data CHDO value field.; Number of bytes after this item.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ref_rcv_type</name>
                    <field_number>72</field_number>
                    <field_location unit="byte">165</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reference receiver type.; 0 => Unknown; 1 => DTT; 2 => MFR</description>
                </Field_Binary>
                <Field_Binary>
                    <name>fabricated_ul_flag</name>
                    <field_number>73</field_number>
                    <field_location unit="byte">166</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Fabricated uplink flag.; Indicates whether this SFDU was created based on uplink records fabricated in support of 3-way ranging.; 0 => SFDU created using uplink records originally generated by UPL and validated by TTC software; 1 => SFDU created using uplink records fabricated by TTC software </description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_prefit_resid_tol_value</name>
                    <field_number>74</field_number>
                    <field_location unit="byte">167</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Hz</unit>
                    <description>Received carrier pre-fit residual tolerance value.; Value used for setting received carrier pre-fit residual tolerance flag.  Provided by customer.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>75</field_number>
                    <field_location unit="byte">171</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dop_noise</name>
                    <field_number>76</field_number>
                    <field_location unit="byte">173</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Hz</unit>
                    <description>Doppler noise. ; Invalid indicated by value of -1.0.</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>delta_ff</name>
                    <field_number>77</field_number>
                    <field_location unit="byte">177</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Delta-f/f.; Valid only for UPL-DTT antennas.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rcv_sig_lvl</name>
                    <field_number>78</field_number>
                    <field_location unit="byte">185</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>dBm</unit>
                    <description>Received signal level.; Carrier power or data power (if suppressed carrier tracking).; (-300.0 if not valid.)</description>
                    <Special_Constants>
                        <invalid_constant>-300.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>num_obs</name>
                    <field_number>79</field_number>
                    <field_location unit="byte">189</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Number of Observable measurements.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>obs_cnt_time</name>
                    <field_number>80</field_number>
                    <field_location unit="byte">191</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Observable count time.  Integration time of the observables.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rcv_carr_obs</name>
                    <field_number>81</field_number>
                    <field_location unit="byte">195</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Sky level Hz</unit>
                    <description>Received Carrier observable.; This measurement is part of a set of measurements that are repeated num_obs times. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_prefit_resid</name>
                    <field_number>82</field_number>
                    <field_location unit="byte">203</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Hz</unit>
                    <description>Received carrier pre-fit residual.; Observed minus predicted.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_prefit_resid_vld_flag</name>
                    <field_number>83</field_number>
                    <field_location unit="byte">207</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Received carrier pre-fit residual validity indicator.; 0 => Invalid pre-fit residual data; 1 => Valid pre-fit residual data</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_prefit_resid_tol_flag</name>
                    <field_number>84</field_number>
                    <field_location unit="byte">208</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Received carrier pre-fit residual tolerance flag.; 0 => Out of tolerance; 1 => In tolerance; 2 => Not applicable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve4</name>
                    <field_number>85</field_number>
                    <field_location unit="byte">209</field_location>
                    <data_type>UnsignedBitString</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Reserved.; Four bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve8</name>
                    <field_number>86</field_number>
                    <field_location unit="byte">213</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Reserved.; Eight bytes.</description>
                </Field_Binary>

            </Record_Binary>         
        </Table_Binary>

        <Table_Binary>
            <local_identifier>trk_TableBinary_SFDU_17</local_identifier>
            <offset unit="byte">25290616</offset>
            <records>30689</records>
            <Record_Binary>
                <fields>91</fields>
                <groups>0</groups>
                <record_length unit="byte">236</record_length>
                <Field_Binary>
                    <name>control_auth_id</name>
                    <field_number>1</field_number>
                    <field_location unit="byte">1</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Control authority identifier. ;  NJPL  indicates that the data description information for this SFDU is maintained and disseminated by NASA/JPL.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_version_id</name>
                    <field_number>2</field_number>
                    <field_location unit="byte">5</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU label version ID.;  2  indicates that the length attribute field in bytes 12 to 19 is formatted as a binary unsigned integer.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_class_id</name>
                    <field_number>3</field_number>
                    <field_location unit="byte">6</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>SFDU class ID.;  I  indicates that this SFDU contains data to be used by an application process.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>4</field_number>
                    <field_location unit="byte">7</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>data_description_id</name>
                    <field_number>5</field_number>
                    <field_location unit="byte">9</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Data description identifier.; Uniquely identifies the data description information held by the control authority identified in the  Control authority identifier  item for this type of SFDU.; C123 => Uplink types; C124 => Downlink types; C125 => Derived types; C126 => Interferometric types; C127 => Filtered types</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sfdu_length</name>
                    <field_number>6</field_number>
                    <field_location unit="byte">13</field_location>
                    <data_type>UnsignedMSB8</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the tracking data SFDU.; Indicates the length of the data following this element.; DT0 => 162; DT1 => 358 ; DT2 => 194 ; DT3 => 304 ; DT4 => 276 ; DT5 => 388 ; DT6 => 200; DT7 => 330; DT8 => 178 ; DT9 => 124; DT10 => 204 ; DT11 => 182; DT12 => 164 ; DT13 => 160; DT14 => 348; DT15 => 194; DT16 => 182 + 18 * num_obs; DT17 => 194 + 22 * num_obs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>7</field_number>
                    <field_location unit="byte">21</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the aggregation CHDO.; A value of 1 indicates that this CHDO is an aggregation of CHDOs</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>8</field_number>
                    <field_location unit="byte">23</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the aggregation CHDO.; Indicates the length of the sum of the primary and secondary CHDOs.; CHDO 132 => 78; CHDO 133 => 122; CHDO 134 => 136; CHDO 135 => 100; CHDO 136 => 110</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>9</field_number>
                    <field_location unit="byte">25</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the primary CHDO.; A value of 2 indicates that this CHDO is a primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>10</field_number>
                    <field_location unit="byte">27</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the primary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the primary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mjr_data_class</name>
                    <field_number>11</field_number>
                    <field_location unit="byte">29</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Major data class.; A value of 6 indicates that the data in this SFDU is ground station monitor data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mnr_data_class</name>
                    <field_number>12</field_number>
                    <field_location unit="byte">30</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Minor data class.; Indicates data is processed tracking data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mission_id</name>
                    <field_number>13</field_number>
                    <field_location unit="byte">31</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Mission ID.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>format_code</name>
                    <field_number>14</field_number>
                    <field_location unit="byte">32</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Format code.; Also referred to as the data type.;   0  =>  Uplink Carrier Phase;   1  =>  Downlink Carrier Phase;   2  =>  Uplink Sequential Ranging Phase;   3  =>  Downlink Sequential Ranging Phase;   4  =>  Uplink PN Ranging Phase;   5  =>  Downlink PN Ranging Phase;   6  =>  Doppler;   7  =>  Sequential Ranging;   8  =>  Angles;   9  =>  Ramps ; 10  =>  VLBI; 11  =>  DRVID ; 12  =>  Smoothed Noise; 13  =>  Allan Deviation; 14  =>  PN Ranging; 15  =>  Tone Ranging; 16  =>  Carrier Observable; 17  =>  Total Phase Observable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>15</field_number>
                    <field_location unit="byte">33</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the secondary CHDO. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>16</field_number>
                    <field_location unit="byte">35</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the secondary CHDO.  Indicates the length, in bytes, of the value field (bytes after this item) of the secondary CHDO.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>orig_id</name>
                    <field_number>17</field_number>
                    <field_location unit="byte">37</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Originator ID.; Indicates where this SFDU was originated. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>last_modifier_id</name>
                    <field_number>18</field_number>
                    <field_location unit="byte">38</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Last modifier ID.; Indicates where this SFDU was last modified. </description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1</name>
                    <field_number>19</field_number>
                    <field_location unit="byte">39</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.  ; For future expansion of scft_id.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_id</name>
                    <field_number>20</field_number>
                    <field_location unit="byte">40</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft number.;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rec_seq_num</name>
                    <field_number>21</field_number>
                    <field_location unit="byte">41</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Record sequence number (RSN).; Begins with zero; increments by one for each successive tracking SFDU of the same type; wraps around from 232-1 to zero. Value is reset to zero when software is restarted.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>year</name>
                    <field_number>22</field_number>
                    <field_location unit="byte">45</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>doy</name>
                    <field_number>23</field_number>
                    <field_location unit="byte">47</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Time tag day of year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>sec</name>
                    <field_number>24</field_number>
                    <field_location unit="byte">49</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Time tag seconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_day</name>
                    <field_number>25</field_number>
                    <field_location unit="byte">57</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Record creation time days.; Days since 1/1/1958.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rct_msec</name>
                    <field_number>26</field_number>
                    <field_location unit="byte">59</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Record creation time milliseconds of day.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>stn_stream_src</name>
                    <field_number>27</field_number>
                    <field_location unit="byte">63</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Station stream source.; 1 => UPL/DTT ; 2 => non-UPL-DTT: TRK?2?30; 3 => non-UPL-DTT: TRK?2?20</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_band</name>
                    <field_number>28</field_number>
                    <field_location unit="byte">64</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink frequency band.; 0 => Unknown or not applicable; 1 => S-band; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_assembly_num</name>
                    <field_number>29</field_number>
                    <field_location unit="byte">65</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink Assembly Number.  ; Note that this is to allow for potential future cases where there might be more than one uplink of the same band at the same antenna.; 0 => Unknown/Not applicable; 1 => S-/X-band uplink; 2 => Ka-band uplink</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_num</name>
                    <field_number>30</field_number>
                    <field_location unit="byte">66</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter number.  ; Value depends on transmitter used. A value of 0 means that the number is unknown or not applicable.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_stat</name>
                    <field_number>31</field_number>
                    <field_location unit="byte">67</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmit Status.; 0 => Not transmitting out the horn; 1 => Transmitting out the horn; 2 => Invalid or unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_mode</name>
                    <field_number>32</field_number>
                    <field_location unit="byte">68</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Transmitter mode.; 0 => Low power; 1 => High power; 2 => Invalid or unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>cmd_modul_stat</name>
                    <field_number>33</field_number>
                    <field_location unit="byte">69</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Command modulation status.; 0 => OFF; 1 => ON; 2 => Invalid or unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rng_modul_stat</name>
                    <field_number>34</field_number>
                    <field_location unit="byte">70</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Ranging modulation status.; 0 => OFF; 1 => ON; 2 => Invalid or unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>transmit_time_tag_delay</name>
                    <field_number>35</field_number>
                    <field_location unit="byte">71</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Transmit time tag delay.  ; Value used to offset uplink time tag (e.g., for Goldstone Beam Waveguide antennas).  A value of -1.0 indicates invalid (or not provided).</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_zheight_corr</name>
                    <field_number>36</field_number>
                    <field_location unit="byte">79</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Uplink Z-height correction.; Value of -99.0 indicates invalid.</description>
                    <Special_Constants>
                        <invalid_constant>-99.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_dss_id</name>
                    <field_number>37</field_number>
                    <field_location unit="byte">83</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Downlink antenna number.;</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve1a</name>
                    <field_number>38</field_number>
                    <field_location unit="byte">84</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reserved.; One byte.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_chan_num</name>
                    <field_number>39</field_number>
                    <field_location unit="byte">85</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Downlink channel number.; Value of 0 implies unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>prdx_mode</name>
                    <field_number>40</field_number>
                    <field_location unit="byte">86</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Predicts mode.; Predicts subset used by downlink channel.; 0 => No Predicts; 1 => One-way; 2 => Two-way; 3 => Three-way; 4 => Unknown</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_prdx_stn</name>
                    <field_number>41</field_number>
                    <field_location unit="byte">87</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink station used for predicts.; Valid only if prdx_mode is 2 or 3. A value of 0 means that the number is unknown or not valid (e.g., no uplink).</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ul_band_dl</name>
                    <field_number>42</field_number>
                    <field_location unit="byte">88</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Uplink frequency band assumed by downlink.; Uplink band value used by downlink for turn around computations.; 0 => Unknown or not applicable; 1 => S-band ; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band</description>
                </Field_Binary>
                <Field_Binary>
                    <name>array_delay</name>
                    <field_number>43</field_number>
                    <field_location unit="byte">89</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Array delay value.  ; Time delay added to path by arraying equipment.  Obtained from arraying equipment.  Any measurements include this delay.  Valid only if Array Flag  (array_flag) is non-zero.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>fts_vld_flag</name>
                    <field_number>44</field_number>
                    <field_location unit="byte">97</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Frequency and Timing (FTS) validity.; 0 => Equipment is not synced with FTS; 1 => Equipment is synced with FTS</description>
                </Field_Binary>
                <Field_Binary>
                    <name>carr_lock_stat</name>
                    <field_number>45</field_number>
                    <field_location unit="byte">98</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Carrier lock status.; 0 => Off; 1 => Open (using only predicts); 2 => Acquiring, FFT Search; 3 => Acquiring, Waiting for Lock Decision; 4 => In Lock; 5 => Out of Lock</description>
                </Field_Binary>
                <Field_Binary>
                    <name>array_flag</name>
                    <field_number>46</field_number>
                    <field_location unit="byte">99</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Array flag.; 0 => Non-arrayed; 1 => Arrayed with FSP #1; 2 => Arrayed with FSP #2</description>
                </Field_Binary>
                <Field_Binary>
                    <name>lna_num</name>
                    <field_number>47</field_number>
                    <field_location unit="byte">100</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>LNA Number.; Value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rcv_time_tag_delay</name>
                    <field_number>48</field_number>
                    <field_location unit="byte">101</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Receive time tag delay.  ; Value used to offset downlink time tag (e.g., for Goldstone Beam Waveguide antennas).  A value of -1.0 indicates invalid (or not provided).</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>dl_zheight_corr</name>
                    <field_number>49</field_number>
                    <field_location unit="byte">109</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Downlink Z-height correction.; Value of -99.0 indicates invalid. </description>
                    <Special_Constants>
                        <invalid_constant>-99.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_ul_stn</name>
                    <field_number>50</field_number>
                    <field_location unit="byte">113</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated uplink station.  ;  The uplink station per the validation process.  A value of 0 means that the antenna is unknown or not valid.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_dop_mode</name>
                    <field_number>51</field_number>
                    <field_location unit="byte">114</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated doppler mode.  ; 0 => Unknown or not applicable; 1 => One-way; 2 => Two-way; 3 => Three-way</description>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_scft_coh</name>
                    <field_number>52</field_number>
                    <field_location unit="byte">115</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated spacecraft coherency.  ; 0 => Unknown or not applicable; 1 => Coherent; 2 => Non-coherent; 3 => Transponded, non-coherent</description>
                </Field_Binary>
                <Field_Binary>
                    <name>vld_dl_band</name>
                    <field_number>53</field_number>
                    <field_location unit="byte">116</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Validated downlink frequency band.; 0 => Unknown; 1 => S-band; 2 => X-band; 3 => Ka-band; 4 => Ku-band; 5 => L-band; 6 => S or X band (26m stations)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_lock</name>
                    <field_number>54</field_number>
                    <field_location unit="byte">117</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft transponder lock.; 0 => Unknown; 1 => Out-of-lock; 2 => In Lock</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_num</name>
                    <field_number>55</field_number>
                    <field_location unit="byte">118</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft transponder number.; 0 if unknown, transponder number otherwise.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>56</field_number>
                    <field_location unit="byte">119</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_osc_freq</name>
                    <field_number>57</field_number>
                    <field_location unit="byte">121</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Hz</unit>
                    <description>Spacecraft oscillator frequency.; Spacecraft one?way frequency.  0.0 if unknown.</description>
                    <Special_Constants>
                        <unknown_constant>0.0</unknown_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_delay</name>
                    <field_number>58</field_number>
                    <field_location unit="byte">129</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Spacecraft transponder delay.; Coherent ranging delay.  Value of ?1.0 indicates invalid.</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_turn_num</name>
                    <field_number>59</field_number>
                    <field_location unit="byte">137</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Spacecraft transponder turn around ratio numerator.; A value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_transpd_turn_den</name>
                    <field_number>60</field_number>
                    <field_location unit="byte">141</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Spacecraft transponder turn around ratio denominator.; A value of 0 indicates unknown.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_twnc_stat</name>
                    <field_number>61</field_number>
                    <field_location unit="byte">145</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft two-way non-coherent (TWNC) status.; 0 => Unknown; 1 => OFF; 2 => ON</description>
                </Field_Binary>
                <Field_Binary>
                    <name>scft_osc_type</name>
                    <field_number>62</field_number>
                    <field_location unit="byte">146</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Spacecraft oscillator type.; 0 => Unknown; 1 => AUX OSC (auxiliary oscillator); 2 => USO (ultra-stable oscillator)</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_day</name>
                    <field_number>63</field_number>
                    <field_location unit="byte">147</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Days</unit>
                    <description>Modification time days.; Days since 1/1/1958.  Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>mod_msec</name>
                    <field_number>64</field_number>
                    <field_location unit="byte">149</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>msec</unit>
                    <description>Modification time milliseconds of day. ; Last modification time.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>cnt_time</name>
                    <field_number>65</field_number>
                    <field_location unit="byte">153</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Count time.; Integration time of the counts.  Value of 0 indicates Not Applicable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>version_num</name>
                    <field_number>66</field_number>
                    <field_location unit="byte">157</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Version number.; Version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_version_num</name>
                    <field_number>67</field_number>
                    <field_location unit="byte">158</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-version number.; Sub-version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>sub_sub_version_num</name>
                    <field_number>68</field_number>
                    <field_location unit="byte">159</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Sub-sub-version number.; Sub-sub-version number of the assembly that generated the data.  </description>
                </Field_Binary>
                <Field_Binary>
                    <name>lna_corr_value</name>
                    <field_number>69</field_number>
                    <field_location unit="byte">160</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>LNA Correction Value.; Indicates results of validation of LNA number.; Value of 0 indicates no validation or correction was made, otherwise if non-zero, this value is to be used instead of lna_num .</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_type</name>
                    <field_number>70</field_number>
                    <field_location unit="byte">161</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Type attribute of the Total Count Phase Observables data CHDO.; CHDO contains binary data.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>chdo_length</name>
                    <field_number>71</field_number>
                    <field_location unit="byte">163</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <unit>Bytes</unit>
                    <description>Length attribute of the Total Count Phase Observables data CHDO value field.; Number of bytes after this item.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>ref_rcv_type</name>
                    <field_number>72</field_number>
                    <field_location unit="byte">165</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Reference receiver type.; 0 => Unknown; 1 => DTT; 2 => MFR</description>
                </Field_Binary>
                <Field_Binary>
                    <name>fabricated_ul_flag</name>
                    <field_number>73</field_number>
                    <field_location unit="byte">166</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Fabricated uplink flag.; Indicates whether this SFDU was created based on uplink records fabricated in support of 3-way ranging.; 0 => SFDU created using uplink records originally generated by UPL and validated by TTC software; 1 => SFDU created using uplink records fabricated by TTC software </description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_prefit_resid_tol_value</name>
                    <field_number>74</field_number>
                    <field_location unit="byte">167</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Hz</unit>
                    <description>Total Count Phase pre-fit residual tolerance value.; Value used for setting total count phase pre-fit residual tolerance flag.  Provided by customer.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve2</name>
                    <field_number>75</field_number>
                    <field_location unit="byte">171</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Reserved.; Two bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>dop_noise</name>
                    <field_number>76</field_number>
                    <field_location unit="byte">173</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Hz</unit>
                    <description>Doppler noise. ; Invalid indicated by value of -1.0.</description>
                    <Special_Constants>
                        <invalid_constant>-1.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>delta_ff</name>
                    <field_number>77</field_number>
                    <field_location unit="byte">177</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Delta-f/f.; Valid only for UPL-DTT antennas.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>rcv_sig_lvl</name>
                    <field_number>78</field_number>
                    <field_location unit="byte">185</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>dBm</unit>
                    <description>Received signal level.; Carrier power or data power (if suppressed carrier tracking).; (-300.0 if not valid.)</description>
                    <Special_Constants>
                        <invalid_constant>-300.0</invalid_constant>
                    </Special_Constants>
                </Field_Binary>
                <Field_Binary>
                    <name>num_obs</name>
                    <field_number>79</field_number>
                    <field_location unit="byte">189</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Number of Observable measurements.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>obs_cnt_time</name>
                    <field_number>80</field_number>
                    <field_location unit="byte">191</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Seconds</unit>
                    <description>Observable count time.  Integration time of the observables.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_st_year</name>
                    <field_number>81</field_number>
                    <field_location unit="byte">195</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Total Count Phase observable start time year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_st_doy</name>
                    <field_number>82</field_number>
                    <field_location unit="byte">197</field_location>
                    <data_type>UnsignedMSB2</data_type>
                    <field_length unit="byte">2</field_length>
                    <description>Total Count Phase observable start time day of year.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_st_sec</name>
                    <field_number>83</field_number>
                    <field_location unit="byte">199</field_location>
                    <data_type>IEEE754MSBDouble</data_type>
                    <field_length unit="byte">8</field_length>
                    <unit>Seconds</unit>
                    <description>Total Count Phase observable start time seconds.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_obs_hi</name>
                    <field_number>84</field_number>
                    <field_location unit="byte">207</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles divided by 4294967296</unit>
                    <description>Negative of Total Count Phase observable - High part phase data whole cycles. ; This measurement is part of a set of measurements that are repeated num_obs times.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_obs_lo</name>
                    <field_number>85</field_number>
                    <field_location unit="byte">211</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Total integer phase cycles modulo 4294967296</unit>
                    <description>Negative of Total Count Phase observable - Low part phase data whole cycles. ; This measurement is part of a set of measurements that are repeated num_obs times.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_obs_frac</name>
                    <field_number>86</field_number>
                    <field_location unit="byte">215</field_location>
                    <data_type>UnsignedMSB4</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Fractional phase cycles multiplied by 4294967296</unit>
                    <description>Negative of Total Count Phase observable   Fractional part phase data cycles. ; This measurement is part of a set of measurements that are repeated num_obs times.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_prefit_resid</name>
                    <field_number>87</field_number>
                    <field_location unit="byte">219</field_location>
                    <data_type>IEEE754MSBSingle</data_type>
                    <field_length unit="byte">4</field_length>
                    <unit>Hz</unit>
                    <description>Total Count Phase pre-fit residual.; Observed minus predicted.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_prefit_resid_vld_flag</name>
                    <field_number>88</field_number>
                    <field_location unit="byte">223</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Total Count Phase pre-fit residual validity indicator.; 0 => Invalid pre-fit residual data; 1 => Valid pre-fit residual data</description>
                </Field_Binary>
                <Field_Binary>
                    <name>total_cnt_phs_prefit_resid_tol_flag</name>
                    <field_number>89</field_number>
                    <field_location unit="byte">224</field_location>
                    <data_type>UnsignedByte</data_type>
                    <field_length unit="byte">1</field_length>
                    <description>Total Count Phase pre-fit residual tolerance flag.; 0 => Out of tolerance; 1 => In tolerance; 2 => Not applicable</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve4</name>
                    <field_number>90</field_number>
                    <field_location unit="byte">225</field_location>
                    <data_type>UnsignedBitString</data_type>
                    <field_length unit="byte">4</field_length>
                    <description>Reserved.; Four bytes.</description>
                </Field_Binary>
                <Field_Binary>
                    <name>reserve8</name>
                    <field_number>91</field_number>
                    <field_location unit="byte">229</field_location>
                    <data_type>ASCII_String</data_type>
                    <field_length unit="byte">8</field_length>
                    <description>Reserved.; Eight bytes.</description>
                </Field_Binary>

            </Record_Binary>         
        </Table_Binary>

        
    </File_Area_Observational>
</Product_Observational>
